Automation


Switchgear

 

Safety Technology

 

Commanding and Signalling

 

Control, Display and Operate

 

 

Timing relays

 

 

Safety relays

 

 

Measuring and monitoring relays

 

 

Rotary switches, switch disconnectors

 

 

Small Enclosures CI-K

 

 

Easy control relays

 

 

 

New multi-talents

 

 

 

Expansion and Networking

 

 

 

easy overview

 

 

 

Use in industry

 

 

 

Use in trade

 

 

 

Installation in the control panel door

 

 

 

Circuit diagram entry

 

 

 

Close up of function blocks

 

 

 

Easy-SOFT

 

 

 

easy with ethernet

 

 

 

easy with Field Bus

 

 

 

FAQ

 

 

 

Support Query

 

 

 

Download

 

 

easyControl compact control

 

 

easyHMI: MFD-Titan

 

 

easyHMI: MFD4

 

Switching and Protecting Motors

 

Switching and Protecting High Power


Darwin Technology


Insulated Distribution Boards


Home > Industry > Switchgear > Control, Display and Operate > Easy Control Relays > Circuit diagram entry

 
easy8_schaltplan easy8_schaltplan easy8_schaltplan easy8_schaltplan easy8_schaltplan easy8_schaltplan easy7_ausgaenge easy6_display easy5_speicher easy4_cursor easy3_funktionen easy3_funktionen easy3_funktionen easy3_funktionen easy2_eingaenge easy1_typ

Wiring by mouse click –
circuit diagram and parameter input

 
Input contact "I1"   Input contact "I2"
Input contact 'I1'   Input contact 'I2'

Connect the contact and the coil
 
Select relay coil "Q1"
Connecting the contact and coil   Select relay coil 'Q1'

 

easy operation

Each of the eight selection keys has a defined function. The selected action becomes active with the OK key. The user selects the action to be performed with the four up, down, left and right cursor keys. The ESC key negates the action and the DEL key erases an input. The ALT key is used for the connection lines in the circuit-diagram.

The circuit diagram is tested after it is input in the control relay. The current flow display indicates how the current flows in a contact during the test phase.


 

  easy operating elements
 

easy saves space

There is enough space everywhere for easy. The standard 45 mm size is suitable for use in domestic distribution boards as well as in machine controls.

 

Enabling or inhibiting access

easy is protected with a password. You can use the password to selectively limit access to the circuit diagram and parameters such as timing relay values or time switch settings.

 

Additional remanance

It is not only circuits and parameters which have to be safeguarded when there is a power failure. ‘easy’ also remembers your switch positions and values. The actual value on the counter and the elapsed time on the timing relay can be recorded. easy500/700 features 4 excellent zero-voltage safe hours-run meters. Up to 16 markers, 8 counters, 8 display texts and 6 timing relays can be operated with zero-voltage safe actual values.

easy has an automatic daylight saving time start/end facility for worldwide use. Simply activate the checkbox to activate the feature and the easy will automatically adjust the clock at the start and end of daylight saving time. If there is no fixed rule in place for the start and end date and time, any dates can be used – worldwide.