What do I need to take into account when directly selecting setpoint values with MI4 units ?

 
  • Information on this can be obtained by clicking the question.


How do you enter Configuration mode on MI4 units if the ENTER key has been assigned a macro ?

 
  • By means of special operations during the power-up


How do you exchange data via Profibus DP between a Moeller PLC with a CM4-504/LE4-504/PS416-NET-441 and a Siemens S7/C7?

 
  • Use Siemens system function SFC13/SFC14/SFC15.


How can you display I/O status information and other modules in the DP Configurator, and how do you force the outputs?

 
  • Click on the question to obtain information.


What is the pin assignment of the KPG3-PS3 cable ?

 
  • Click on the question to obtain information.


How can you connect the outputs in parallel on the LE4-116-DD1 and LE4-116-XD1?

 
  • Only the outputs of the same driver should be connected in parallel.


How can you connect a PROFIBUS-DP master and a PROFIBUS-DP slave to the PS4-341-MM1 together?

 
  • Click on the question to obtain information.


How much data can a PS416-NET-440 Profibus DP master card send to each station and how much can it receive ?

 
  • The PS416-NET-440 can receive 244 bytes and send 244 bytes.


What is the current hardware version of the PS3AC and PS3DC ?

 
  • The current hardware version (12/2000) of the PS3AC and PS3DC is : Version 1.7


How is the hardware counter in the PS4-341-MM1 activated and programmed ?

 
  • The PS4-341-MM1 counter is activated and assigned parameters in the Sucosoft S40 Topology Configurator.


How can I connect up an MI4 or MV4 unit via Sucosoft S30 ?

 
  • Use the S30-AM-I40 application modu


Which function does the file PS40_Transfer_Link.DLL support ??

 
  • The file supports additional functions of the file SucomA32.DLL.


Does Sucosoft S40 include the FAlarm function block?

 
  • The EdgeAlarm function block is available instead.


Can Sucosoft S40 also be run on Linux?

 
  • Information on this can be obtained by clicking the question


What temperature monitoring options are available with the PS4 / PS416 system?

 
  • EM4-101-TX1, EM4-101-TX2 remote expansion modules and the PS4-271-MM1 PLC offer temperature measuring features.


How do you implement the short-circuit monitoring of the outputs on the
PS416-OUT-400 / -410 cards ?

 
  • Use a ZAA central monitoring unit


On which PC operating systems does the PROFIBUS-FMS Configurator run ?

 
  • From version 3.3 or higher, MS-Windows 95, MS-Windows 98 and MS-Windows NT. Before this version, only MS-Windows 3.xx.


Is the NG31 still available or is there a similar substitute ?

 
  • A substitute can be obtained directly from the company Hubert Schröter. Click the question to obtain information.


Does the Moeller automation product range include an SSI interface for absolute positioning encoders ?

 
  • The LE4-633-CX1 local expansion module is available for this


How can you implement a connection between an EPC335 card and a PS4?

 
  • Use the KPG3-PS3 cable. Order No.: 014487


How can you map a larger number of I/O to the marker range ?

 
  • Use the


Is there a German version of the Profibus DP Configurator ?

 
  • Click on the question to obtain information.


Can I use the PS416-CPU in the PS316 rack with its I/O cards ?

 
  • Neither the rack nor the I/O-cards of the PS316 series can be used.


Which version of Sucosoft S40 supports: Structured text programming (ST) ?

 
  • From Sucosoft S40; version 5.0


What is the successor of the EM4-101-AA1 ?

 
  • The successor is the EM4-101-AA2


What settings are required to connect an MI4 to a PS4-341 via Suconet K ?

 
  • a) Check MI4 configuration
    b) Check PLC Topology Configurator


I wish to use the CFG-DP V2.0 to configure an XI/ON slave with an analog output(-10V..+10V). However, this was not shown in the module list.

 
  • The reason why the module texts are not shown is that the column width setting inside the module selection window has to be changed.


As take is the MV4 coupling to a Mitsubushi A series PLC ?

 
  • With the communications module AJ71C24


How do you transfer the PLC time to the MV4 ?

 
  • Click on the question to obtain information.


What is with the communication between a MV4 and a Siemens PLC, to heed ?

 
  • Attention: The Bytes are reversed.


Can the PS4-341-MM1 emulate the Sucom-A of the PS316 ?

 
  • Yes, with the PS4-341-MM1 operating system from Sucosoft S40 version 4.0


What is necessary to actuate a contactor coil as an emergency measure when the PLC malfunctions ?

 
  • Decoupling via a protective diode


How is the environment language selected in the MV4 Configurator ?

 
  • In the menue: Config


How can consistent data be received with a Profibus DP master?

 
  • By adjustment of the consistent data length


Can Sucosoft S40; version 4.00 still run on Windows 3.11 ?

 
  • No, since S40 uses 32-bit functions.
    The S40 runs with Windows 95/98 or with Windows NT 4.0


Is it possible to change the analog output of the PS4-271 from a 0-10 V to a 0-20 or 4-20 mA signal using an 500 Ohm resistor ?

 
  • No, since only 5 mA is provided at the analog output.


Can the S40 OPC Server V1.0 for Windows NT copied to
hard disk drive E too with 1.26 GB free memory ?

 
  • Yes, please further information heeds. (Clicks the question)


Is it possible to set the panel brightness of the MI4-471-TC1 touch panel ?

 
  • Unfortunately not with this type !


Can the DE4-CFG-200 configuration software be ordered separately?

 
  • The DE4-CFG-200 configuration software cannot be ordered separately. It is part of the documentation (AWB823-1279-D/GB/F) of the DE4-COM-2X serial interface and is supplied on CD.


Is it possible to use the DE4-NET-K network module with DF4-120 frequency inverters ?

 
  • The DE4-NET-K network module cannot be used with DF4-120 frequency inverters. The module is used to connect the DF4-340 and DF4-341 frequency inverters directly to the Suconet K fieldbus.


When should motor chokes be used ?

 
  • When long motor feeders are involved. These are used to reduce the edge steepness of the inverter output voltage.


Should a mains choke always be used ?

 
  • It is recommended. With some frequency inverters this is absolutely necessary.


When are radio suppression filters used?

 
  • Please click on the question to obtain further infomation !


What should be taken into account with the cyclical mains switching of frequency inverters ?

 
  • Frequency inverters should be switched on at most once every 3 minutes otherwise the internal inrush current limit will be exceeded.


When should sinusoidal filters be used?

 
  • When the frequency inverter is to supply a sinusoidal output voltage. With long motor feeders. To reduce the edge steepness of the inverter output voltage.


How is the EASY205-ASI addressed ?

 
  • Click the question to obtain further information.


How much and which data can the EASY205-ASI exchange with the AS-Interface master ?

 
  • As with all AS-i-slaves, a maximum of 4 input bits, 4 output bits and 4 parameter bits (from the point of view of the AS-i-master) can be transported between the master and slave (EASY205-ASI).


How do you use the contacts and coils designated as ?

 
  • R stands for the inputs of the expansion units and S for the outputs of the expansion units.


Can the outputs of the EASY..-D.-T.. units be provided with short-circuit monitoring?

 
  • Yes, using inputs I15, I16, R15, R16 depending on the EASY type.


Is there a demo version of EASY-Soft and what are its restrictions compared to the full version ?

 
  • Yes, there is a demo version of EASY-Soft.
    Click the link below to download it.


How can you prepare your own Suconet K/K1 cable ?

 
  • Use LT309.096 cable and connector S1-PS3.


How many circuit connections can EASY412-... and EASY6..-... units support ?

 
  • EASY412 units can support 41 circuit connections and
    EASY6..-... units 121.


How can PLCs be provided with serial interfaces ?

 
  • The ZB4-501-UM3 and ZB4-501-UM4 interface converters can be used for this purpose


How can closed-loop control tasks be implemented with the PS4/PS416 PLC systems ?

 
  • There are two application modules with two-point controllers, three-point controllers, PID controllers and there is a closed-loop control toolbox for complex closed-loop control.


Is there an OPC interface for Moeller PS4/PS416 programmable controllers ?

 
  • The S40 OPC-server interface is available for the PS4/PS416 programmable controllers.


How can the PS4/PS416 system receive and evaluate the DCF77 radio time signal ?

 
  • A DCF77 receiver is required for receiving the DCF77 radio time signals and a software is required for evaluating the signal.


What is an application module?

 
  • An application module contains software function blocks for the PLC. These software modules offer solutions for standard automation tasks.


What cable can be used for PROFIBUS-DP ?

 
  • Click the question to obtain the technical data of the cable.


How many characters can be entered in the comment field in the POU Editor under POU Info ?

 
  • The comment field of the POU is 15 KByte.


Is it possible to carry out remote diagnostics for the PS4/PS416 system ?

 
  • Remote diagnostics can be carried out using a modem connection between the programming device and the PLC.


Is it possible to run a Suconet K2 line with the PS416 ?

 
  • The PS416-NET-210 Suconet K1/K2 card and the S40-AM-K2-D/GB application module are required for running Suconet K2 with the PS416.


How can I send and receive SMS messages with the PS4/PS416 system?

 
  • SMS application modules (software function blocks) allow SMS messages (SMS = Short Message Service) to be sent and received.


Do the PS4 compact PLCs have a MODBUS/JBUS interface ?

 
  • A MODBUS/JBUS interface can be implemented using the S40-AM-K4-D/GB application module and an interface converter.


How can large volumes of data be transferred via Suconet K or PROFIBUS-DP ?

 
  • The Suconet K/PROFIBUS-DP data multiplexer application module enables the transfer of large data volumes.


Is it possible to carry out floating point arithmetic operations with PS4 compact PLCs ?

 
  • Floating point arithmetic is a basic function of the PS4-341-MM1. With the PS4-150/200 you can use the S40-AM-A1-D/GB application module to implement floating point arithmetic functions.


How can the ″S″ outputs of the expansion units otherwise be used ?

 
  • If the Easy basic unit is used without expansion units, the ″S″ outputs can be used as additional markers.


Which memory module version can be used in the PS4-341-MM1 as a space ?

 
  • Note: verify PS4-341-MM1 version number.


What is OPC ?

 
  • OLE for Process Control


Can the Sucom_A functionblock be used on the PS4-... MM1 in order to program the PLC with Sucosoft S40 ?

 
  • No


Is there a data multiplexer for Suconet-K / PROFIBUS-DP ?

 
  • Yes, the application module S40-AM-K1-GB contents a data multiplexer for Suconet-K / PROFIBUS-DP.


Which PS4 type can be equipped with the PROFIBUS-DP master module ?

 
  • Only the PS4-341-MM1.


Is it possible to expand the memory of a MI4-471-TC1 Touch Panel
with a 2 or 4 MByte memory ZB4-902-SF1 or ZB4904-SF1?

 
  • Yes


What is the type designation of the spare memory module for the ZB4-901-SF1 ?

 
  • ZB4-901-SF2


Where can I get the latest Sucosoft S40 Service Pack?

 
  • From the MOELLER FTP Server, please click on the question.


How is the current version of the Profibus-DP Configurator for S40 available ?

 
  • Over download, please click on the question.


What is the maximum number of slave stations that can be run with the
LE4-504-BS1 (PROFIBUS-DP master) ?

 
  • 124 Slaves


Why is the MV4-Configurator only available with the type MV4-CFG-1 ?

 
  • MV4-CFG-1-GB


Which available MV4-devices are not listed in Main Catalogue ?

 
  • Typen: MV4-590-TA1 und /TA2 und /-XX1


Which touch panels are available in stainless steel?

 
  • MV4 Touch panels.


Test Intranet access

 
  • Test Intranet access


How many LE4-505-BS1 and CM4-505-GS1 AS-Interface masters can be connected to a PS4-... ?

 
  • Click on the question to obtain information.


Can several telecontrol modules ZB4-501-TC2 be connected to a Suconet line ?

 
  • The ZB4-501-TC2 can connect up to 14 on a Suconet line.


Is it possible to implement an MV4 interface via Device Net ?

 
  • Yes, with MV4 configurator MV4-CFG-1 since version 3.12.4 and a communication card ZB4-606-IF1.


What should be done if the write protection in the MV4 standard recipe management function cannot be removed ?

 
  • Only possible with MV4 configurator MV4-CFG-1 from version 3.12.


Can several interface converters be connected to a Suconet line ?

 
  • Yes, the ZB4-501-UM4 allows up to 14 to be connected in a Suconet line. The conversion is from Suconet K to RS232.


Which PLC types can be connected to the ZB4-501-UM4 ?

 
  • PS4-150/-200/-300 and PS416 series.


How can PS4 compact PLCs be expanded locally?

 
  • The PS 4 compact PLCs are expanded with LE4-. . . expansion modules.


What design measures are required to integrate an LE4-504-BT1 (PROFIBUS-DP Slave) in a STEP 7 hardware configuration?

 
  • The design measures for integrating an LE4-504-BT1 (PROFIBUS-DP Slave) in a STEP 7 hardware configuration are shown in a video that can be downloaded.


How can a message be printed out on MI4 display and operator systems?

 
  • Information on this is provided in an application note that can be obtained free-of-charge from the Internet.


How can an MI4 operator panel be connected to a Siemens S7 PLC?

 
  • An MI4 operator panel can be connected to a Siemens S7 PLC via MPI.


How can an MV4 touch panel be connected to a Siemens S7 PLC?

 
  • An MV4 touch panel can be connected to a Siemens S7 PLC using PROFIBUS-DP.


What are the chemical substances that the front of the MV4 touch operator panel is resistant to?

 
  • Click the question to obtain information on the chemical resistance of the MV4 front panel.


How can PS4/PS416 systems be networked with PROFIBUS-FMS?

 
  • Different modules/cards are available for networking PS4/PS416 systems with PROFIBUS-FMS. Click the question to obtain further information.


How can the PS416 networked with PROFIBUS-PA?

 
  • The PS416 can be networked with PROFIBUS-PA using a segment coupler.


How are PS416 systems networked using the PS416-NET-400 Suconet K network card?

 
  • Click the question above to obtain a description of the networking of PS416 systems.


Is it possible to synchronize the time between several MI4 display and operator units?

 
  • Yes! This is described in an application note that is available from the Internet.


To which PLC types can the ZB4-501-TC2 be connected ?

 
  • The ZB4-501-TC2 can be connected on the PS4-150/-200/-300 and PS416 series.


Is there any presentation material for the MI4-display and operating units ?

 
  • Yes


What languages are containd in the EASYSOFT upgrade, version 3.1 ?

 
  • German, English, Spanish, French, Italian, Portuguese


From which operating system version (OS) of an EASY6 can an EASY204-DP Profibus-DP slave communication module be connected ?

 
  • OS version 2.4


What EASY power supply unit can be used to provide the DC control relays
with a + 24V supply ?

 
  • EASY400-POW


Which components are containd in the EASY620-TB-GB trainer box and in which languages is it available ?

 
  • Click the question to obtain further information.


Is there a new version of EASY-SOFT for addressing the EASY204-DP ?

 
  • Yes, click the question to the download.


Can the CoBox also be run on the Suconet (RS485) interface?

 
  • On the PS4-341-MM1 the CoBox can also be run directly on the Suconet interface if the SucomA function block is called in Transparent mode.


Is there a software to support the PROFIBUS-DP link of the Easy control relay to the EASY204-DP module with a MOELLER control system PS4 / PS416 ?

 
  • The S40-AM-K6-D/GB application module is provided for this purpose. Click the question to obtain the application module via the Internet.


Is the software for configuring MI4 display and control devices compatible to Windows 2000 and Windows NT?

 
  • Yes, from version 2.01


What is the meaning of the flashing DEF-Dirty LED on the MV4 ?

 
  • When this LED is flashing, either the IR frame is slightly dirty or an IR sensor has failed. The flashing LED is only a warning.


What should be remembered on the MV4 Touch Operator Panel in order to prioritize the ″Print Report″ function while the ″Print Online Errors″ function is active ?

 
  • Click the question to obtain further information.


Can the PS4/PS416 communicate via Ethernet ?

 
  • For the communication with Ethernet is the network-module ″COBOX″ available.


Can the PS4-151-MM1 be mounted and run in a vertical position?

 
  • Yes, the vertical mounting position is possible if the interfaces (PRG / Suconet) are towards the bottom.


Which PS416 cards can be used in the PS316 ?

 
  • The following PS416 cards were tested and released for the PS316 series:
    PS416-INP-400, PS416-INP-401
    PS416-OUT-400, PS416-OUT-401


Which MI4-units and frequency inverters are supported from Sucosoft S40, Version V4.21 ?

 
  • Click the question to obtain further information.


With which operating system is EASY-SOFT V3.1 compatible ?

 
  • Windows 95 / 98 and Windows NT 4.0 (Service-Pack 3 and higher).


What is the name of the application module for data exchange between the EASY204-DP and PS4-341/PS416 ?

 
  • The application module is called S40-AM-K6-D/GB.


Which MI4 Operator Panels are approved by the Underwriters Laboratories (UL) and for the Canadian market (C UL) ?

 
  • You see table:


Is there an electronic of the Moeller Catalogue available on CD-ROM ?

 
  • Yes, click the question to obtain further information.


Is there a Powerpoint presentation available for the S40-OPC-Server ?

 
  • Yes; opcser_g.ppt


Which PLC types can be connected to the S40-OPC-Server as clients ?

 
  • PS4-141/-151/-201/-271/-341-MM1as well as the PS416


Which connection interfaces are possible for connection between the PC (S40-OPC-Server) and PLC (Clients) ?

 
  • Click the question to obtain further information.


How can the analog values of the potentiometers on PS4 controllers be converted to TIME type variables?

 
  • Click the question to obtain further information.


What is the application module required for data exchange between the PS40 controller via Ethernet?

 
  • The application module is: S40-AM-K5-GB, to download please click on the question.


What hardware (PLC) can be used with the Positioning Toolbox ?

 
  • PS4-341-MM1 and PS416


What are the function changes of version 2.04 of MI4-CFG-1-D/GB ?

 
  • Click the question to obtain further information.


How can I reach the version 2.04 of the MI4-Generier-Software MI4-CFG-1 ?

 
  • A Download is possible with clicks the question.


Where are the version lists for Moeller PS4/PS416, EM4, LE4, Sucosoft and MI4/MV4 ?

 
  • With clicks the question you reach the current version lists.


What is the name of the manual for AS-i Profibus-Gateways (CM4-505-GV1/GV2) ?

 
  • The article-number is AWB2700-1409-GB.
    The manual is available on the Moeller homepage => support => Quick Search to: CM4-505.


Which EASY-SOFT version can be used for programming Profibus-DP Interface ?

 
  • Version V3.1 and higher!


Is there a DEMO version for the MV4 Configurator (Galileo) ?

 
  • Yes, with clicks the question you reach the download.


What are the functional changes in the MV4-CFG-1-D/GB version V4.00.1 ?

 
  • See answer!


What is the application module for Ethernet data coupling with the
PS4-150/-200/-341 and PS416 ?

 
  • Yes, the application module S40-AM-K5-GB. With clicks the question to download.


What has to be observed when a PS416-MEM-442 or PS416-MEM-443 memory module is ordered ?

 
  • See answer!


What is the EASY expansion unit for 2 additional relay outputs called ?

 
  • EASY202-RE


Does the EASY202-RE expansion unit require its own voltage supply ?

 
  • No: This is supplied directly from the basic unit.


Which EASY types are approved by RINA (Registro Italiano Navale), the Italian register of shipping ?

 
  • 8 EASY types (see the answer)


Which LE4-... modules have a CSA approval (Status: November 2001) ?

 
  • All the LE4-... modules which are in the Main Catalogue 2002: Automatisierungstechnik, Antriebstechnik have CSA approval.


What must be done when the Sucosoft S40 V4.xx will not start in conjunction with network printers running under WIN2000 ?

 
  • Click the question to obtain further informations.


Which termination resistance values are required with PROFIBUIS-DP ?

 
  • 390 Ohms / 220 Ohms / 390 Ohms


How high is the level of input impedance with the PS4-..., LE4-..., EM4-100/200 and the PS416-INP400/401 input module ?

 
  • With the PS4-..., EM4-... and PS416-... the input impedance is 6.5 kOhms, with LE4-... the input impedance is 4.1 kOhms


Can masks used on MV4-xxx and MI4-xxx touch panels burn the display if they are displayed continuously over a long period ?

 
  • Yes