Australian Catalogue


CAD Blocks


Marechal


PDF Catalogues


AWA Installation Instructions


Moeller Wiring Manual


Downloads


FAQs

   

Home > Support > FAQs
 
       
Search:
Find: or and Suche  

Note: All links below take you to our German site, if you want to navigate back to the Australian site, use the Back button on your browser.
 
34 entries found.
 

How can you connect a PROFIBUS-DP master and a PROFIBUS-DP slave to the PS4-341-MM1 together?

 
  • Click on the question to obtain information.


How is the hardware counter in the PS4-341-MM1 activated and programmed ?

 
  • The PS4-341-MM1 counter is activated and assigned parameters in the Sucosoft S40 Topology Configurator.


Is the NG31 still available or is there a similar substitute ?

 
  • A substitute can be obtained directly from the company Hubert Schröter. Click the question to obtain information.


How can you implement a connection between an EPC335 card and a PS4?

 
  • Use the KPG3-PS3 cable. Order No.: 014487


What settings are required to connect an MI4 to a PS4-341 via Suconet K ?

 
  • a) Check MI4 configuration
    b) Check PLC Topology Configurator


Can the PS4-341-MM1 emulate the Sucom-A of the PS316 ?

 
  • Yes, with the PS4-341-MM1 operating system from Sucosoft S40 version 4.0


What is necessary to actuate a contactor coil as an emergency measure when the PLC malfunctions ?

 
  • Decoupling via a protective diode


How can you prepare your own Suconet K/K1 cable ?

 
  • Use LT309.096 cable and connector S1-PS3.


How can PLCs be provided with serial interfaces ?

 
  • The ZB4-501-UM3 and ZB4-501-UM4 interface converters can be used for this purpose


How can closed-loop control tasks be implemented with the PS4/PS416 PLC systems ?

 
  • There are two application modules with two-point controllers, three-point controllers, PID controllers and there is a closed-loop control toolbox for complex closed-loop control.


Which memory module version can be used in the PS4-341-MM1 as a space ?

 
  • Note: verify PS4-341-MM1 version number.


Can the Sucom_A functionblock be used on the PS4-... MM1 in order to program the PLC with Sucosoft S40 ?

 
  • No


Which PS4 type can be equipped with the PROFIBUS-DP master module ?

 
  • Only the PS4-341-MM1.


What is the type designation of the spare memory module for the ZB4-901-SF1 ?

 
  • ZB4-901-SF2


How many LE4-505-BS1 and CM4-505-GS1 AS-Interface masters can be connected to a PS4-... ?

 
  • Click on the question to obtain information.


How can PS4 compact PLCs be expanded locally?

 
  • The PS 4 compact PLCs are expanded with LE4-. . . expansion modules.


What design measures are required to integrate an LE4-504-BT1 (PROFIBUS-DP Slave) in a STEP 7 hardware configuration?

 
  • The design measures for integrating an LE4-504-BT1 (PROFIBUS-DP Slave) in a STEP 7 hardware configuration are shown in a video that can be downloaded.


How can PS4/PS416 systems be networked with PROFIBUS-FMS?

 
  • Different modules/cards are available for networking PS4/PS416 systems with PROFIBUS-FMS. Click the question to obtain further information.


Can the CoBox also be run on the Suconet (RS485) interface?

 
  • On the PS4-341-MM1 the CoBox can also be run directly on the Suconet interface if the SucomA function block is called in Transparent mode.


Can the PS4/PS416 communicate via Ethernet ?

 
  • For the communication with Ethernet is the network-module ″COBOX″ available.


Which PLC types can be connected to the S40-OPC-Server as clients ?

 
  • PS4-141/-151/-201/-271/-341-MM1as well as the PS416


Which connection interfaces are possible for connection between the PC (S40-OPC-Server) and PLC (Clients) ?

 
  • Click the question to obtain further information.


How can the analog values of the potentiometers on PS4 controllers be converted to TIME type variables?

 
  • Click the question to obtain further information.


What is the application module required for data exchange between the PS40 controller via Ethernet?

 
  • The application module is: S40-AM-K5-GB, to download please click on the question.


What hardware (PLC) can be used with the Positioning Toolbox ?

 
  • PS4-341-MM1 and PS416


Where are the version lists for Moeller PS4/PS416, EM4, LE4, Sucosoft and MI4/MV4 ?

 
  • With clicks the question you reach the current version lists.


What is the application module for Ethernet data coupling with the
PS4-150/-200/-341 and PS416 ?

 
  • Yes, the application module S40-AM-K5-GB. With clicks the question to download.


How high is the level of input impedance with the PS4-..., LE4-..., EM4-100/200 and the PS416-INP400/401 input module ?

 
  • With the PS4-..., EM4-... and PS416-... the input impedance is 6.5 kOhms, with LE4-... the input impedance is 4.1 kOhms


What is the permissible power supply range for the PS4-.../EM4-... and LE4-... devices ?

 
  • With 24V power supply (DC), from 20.4 to 28.8 V
    With 115 to 230 V power supply (AC): from 98 to 264 V


Is there an update for the closed-loop control toolbox ?

 
  • Yes, please click on the question to reach the download.


How do you declare a function block in S40 as retentive ?

 
  • Please click on the question to obtain further information.


Can a PS4 or PS416 program be SAVED/RESTORED (packed/unpacked) ?

 
  • Yes, with the function: SAVE in the S40 navigator.


How do you read or write the inputs and outputs of the PS4 controller directly?

 
  • With direct peripheral access. Please click on the question to obtain further information !


How do you determine the reaction time of a PS4 controller?

 
  • By adding together the input delay, maximum PLC cycle time and output delay. Please click on the question to obtain further information!

 

 

 

.
 
 

 

 


Privacy Policy © 2007 by Moeller GmbH   Top