How do you exchange data via Profibus DP between a Moeller PLC with a CM4-504/LE4-504/PS416-NET-441 and a Siemens S7/C7?

 
  • Use Siemens system function SFC13/SFC14/SFC15.


How can you connect a PROFIBUS-DP master and a PROFIBUS-DP slave to the PS4-341-MM1 together?

 
  • Click on the question to obtain information.


How much data can a PS416-NET-440 Profibus DP master card send to each station and how much can it receive ?

 
  • The PS416-NET-440 can receive 244 bytes and send 244 bytes.


Which function does the file PS40_Transfer_Link.DLL support ??

 
  • The file supports additional functions of the file SucomA32.DLL.


How can you implement a connection between an EPC335 card and a PS4?

 
  • Use the KPG3-PS3 cable. Order No.: 014487


How can you map a larger number of I/O to the marker range ?

 
  • Use the


How can consistent data be received with a Profibus DP master?

 
  • By adjustment of the consistent data length


Can the S40 OPC Server V1.0 for Windows NT copied to
hard disk drive E too with 1.26 GB free memory ?

 
  • Yes, please further information heeds. (Clicks the question)


How can PLCs be provided with serial interfaces ?

 
  • The ZB4-501-UM3 and ZB4-501-UM4 interface converters can be used for this purpose


Is there an OPC interface for Moeller PS4/PS416 programmable controllers ?

 
  • The S40 OPC-server interface is available for the PS4/PS416 programmable controllers.


What cable can be used for PROFIBUS-DP ?

 
  • Click the question to obtain the technical data of the cable.


Is it possible to run a Suconet K2 line with the PS416 ?

 
  • The PS416-NET-210 Suconet K1/K2 card and the S40-AM-K2-D/GB application module are required for running Suconet K2 with the PS416.


What is OPC ?

 
  • OLE for Process Control


Which PS4 type can be equipped with the PROFIBUS-DP master module ?

 
  • Only the PS4-341-MM1.


What is the maximum number of slave stations that can be run with the
LE4-504-BS1 (PROFIBUS-DP master) ?

 
  • 124 Slaves


How many LE4-505-BS1 and CM4-505-GS1 AS-Interface masters can be connected to a PS4-... ?

 
  • Click on the question to obtain information.


Can several telecontrol modules ZB4-501-TC2 be connected to a Suconet line ?

 
  • The ZB4-501-TC2 can connect up to 14 on a Suconet line.


Can several interface converters be connected to a Suconet line ?

 
  • Yes, the ZB4-501-UM4 allows up to 14 to be connected in a Suconet line. The conversion is from Suconet K to RS232.


Which PLC types can be connected to the ZB4-501-UM4 ?

 
  • PS4-150/-200/-300 and PS416 series.


How can PS4 compact PLCs be expanded locally?

 
  • The PS 4 compact PLCs are expanded with LE4-. . . expansion modules.


What design measures are required to integrate an LE4-504-BT1 (PROFIBUS-DP Slave) in a STEP 7 hardware configuration?

 
  • The design measures for integrating an LE4-504-BT1 (PROFIBUS-DP Slave) in a STEP 7 hardware configuration are shown in a video that can be downloaded.


How can PS4/PS416 systems be networked with PROFIBUS-FMS?

 
  • Different modules/cards are available for networking PS4/PS416 systems with PROFIBUS-FMS. Click the question to obtain further information.


How can the PS416 networked with PROFIBUS-PA?

 
  • The PS416 can be networked with PROFIBUS-PA using a segment coupler.


How are PS416 systems networked using the PS416-NET-400 Suconet K network card?

 
  • Click the question above to obtain a description of the networking of PS416 systems.


To which PLC types can the ZB4-501-TC2 be connected ?

 
  • The ZB4-501-TC2 can be connected on the PS4-150/-200/-300 and PS416 series.


Which PLC types can be connected to the S40-OPC-Server as clients ?

 
  • PS4-141/-151/-201/-271/-341-MM1as well as the PS416


Which LE4-... modules have a CSA approval (Status: November 2001) ?

 
  • All the LE4-... modules which are in the Main Catalogue 2002: Automatisierungstechnik, Antriebstechnik have CSA approval.


What is the name of the documentation for the LON-LE (LE4-509-BS1) ?

 
  • Please click on the question to obtain further information.


How can Moeller PLCs be connected to SCADA or visualisation systems of other manufacturers ?

 
  • SCADA/visualisation systems with an OPC-Interface can be linked directly to a Moeller PLC using the S40-OPC server. Data transfer is implemented via RS232, modem or Ethernet TCP/IP.


What is the simplest way of exchanging data (e.g. for visualisation) between a PLC and a PC?

 
  • Using the Sucoma_32 driver, download with click on the question

 

 

 

.
 
 

 

 