I/O module with temperature measurement

 

 

 

MFD-Titan with Ethernet

 

 

 

Expansion and networking

 

 

 

EASY-SOFT-PRO

 

 

 

Select: Device types/Technical data

 

 

 

Support Query

 

 

 

Download

 

 

easyHMI: MFD4

 

Switching and Protecting Motors

 

Switching and Protecting High Power


Darwin Technology


Insulated Distribution Boards


Home > Industry > Switchgear > Control, Display and Operate > easyHMI: MFD-Titan > I/O module with temperature measurement

MFD-Titan: Input/output modules with temperature measurement

input/output modules with temperature measurement Using the temperature modules MFD-TP…/MFD-TAP… you can now directly connect PT100 and NI1000 temperature sensors directly to the MFD-Titan. Thus, the indirect method utilising an expensive temperature measurement amplifier is avoided.

The temperatures are measured with a 12 bit resolution and can be assigned to temperature ranges from -200 °C to 850 °C.
MFD-TP…

You also have the option of selecting 2-wire or 3-wire connection of temperature sensors.

Programming is implemented in the usual manner using the wiring diagram entry via the EasySoft programming software.

 

Technical data

Analog inputs for Pt100 or Ni1000 resistance temperature sensors
Quantity 2 x Pt100 or 2 x Nt1000 (depending on the type)
Resistance sensor input type
 
 
– Platinum sensor Pt100 according to
   DIN EN 60751, IEC 751
 
– Nickel sensor Ni1000 according to
   DIN 43760
 
Temperature ranges  
– Pt100, range A, selectable °C, (°F) -40 to +90, (-40 to 194); 0 to 250,
(32 to 482); 0 to 400, (32 to 752)
– Ni1000, range A, selectable °C, (°F) -40 to +90, (-40 to 194); 0 to 250, (32 to 482)
– Pt100, range B
°C, (°F)
0 to 850, (32 to 1562); -200 to 200,
(-328 to 392)
Digital resolution, scaling per sensor  
– With operand „IA“ and „MD“,
   selectable under scalling
Bit 12 (0 to 4095)
– With operand "MD",
   selectable under scaling
°C, (°F)
1, 0,1, (1), (0,1)
Measurement method Selectable two wire or three wire per sensor, using the sensor connections

 

Here you find your application!
 
Exchange information with other users in the MFD-Forum!
 
  Note: You will exit the moeller.net with this link. Moeller GmbH does not assume any responsibility for the content and design of the linked pages.
 
 
 
 
 


Privacy Policy © 2007 by Moeller GmbH   Top