Technical Data Overview
 |
 |
 |
|
|
MFD-Titan
|
|
MFD...
|
80
|
80-B
|
CP4
-500
-800
|
CP8
-ME
-NT |
AC- CP8
-ME
-NT
|
R16
AC
-R16
|
RA17
|
TA16
|
TA17
|
|
Application |
Display
|
Power supply/ Coupling
|
Power supply/CPU
|
Inputs-/Outputs
|
|
Supply-voltage |
MFD-CP...
|
24 V DC
|
100 –
240 V AC
|
Supply via ...-CP8-...
|
|
Heat dissipation
|
3 W
|
1.5 W
|
3 W
|
8 V A
|
0.5 W
|
|
Inputs,
digital
|
–
|
–
|
–
|
–
|
–
|
12
|
Inputs,
analog,
option. (0-10 V) |
–
|
–
|
–
|
–
|
–
|
4/–
|
4
|
4
|
4
|
Outputs,
digital (R=relay
T=transistor)
|
–
|
–
|
–
|
–
|
–
|
4 R
|
4 R
|
4 T
|
4 T
|
Outputs,
analog,
(0-10 V) |
–
|
–
|
–
|
–
|
–
|
–
|
1
|
–
|
1
|
|
LC-Display, Keypad EASY-
Keypad EASY-X |
Yes/–
|
Yes/Yes
|
–
|
–
|
–
|
–
|
–
|
–
|
–
|
Week-/
Year timer |
–/–
|
–/–
|
–/–
|
Yes/Yes
|
Yes/Yes
|
–/–
|
–/–
|
–/–
|
–/–
|
Continuous
current outputs
|
–
|
–
|
–
|
–
|
–
|
8 A
|
8 A
|
0,5 A
|
0,5 A
|
|
Short-circuit proof
with power
factor 1
|
–
|
–
|
–
|
–
|
–
|
Line protection
B 16, 600 A
|
–
|
–
|
|
Short-circuit proof
with power factor
0.5...0.7
|
–
|
–
|
–
|
–
|
–
|
Line protection
B 16, 900 A
|
–
|
–
|
Dimensions
(W x H x D)
|
86.5 x 86.5 x 20 mm
|
78 x 58 x 36.2 mm
|
107.5 x 90 x 29.5 mm
|
88.1 x 90 x 25 mm
|
|
|
 |
 |
 |

|