Jump to:

  1. How is the EASY205-ASI addressed ?

  2. How much and which data can the EASY205-ASI exchange with the AS-Interface master ?

  3. How do you use the contacts and coils designated as ?

  4. Can the outputs of the EASY..-D.-T.. units be provided with short-circuit monitoring?

  5. Is there a demo version of EASY-Soft and what are its restrictions compared to the full version ?

  6. How many circuit connections can EASY412-... and EASY6..-... units support ?

  7. How can the "S" outputs of the expansion units otherwise be used ?

  8. What languages are contained in the EASYSOFT upgrade, version 3.1 ?

  9. From which operating system version (OS) of an EASY6 can an EASY204-DP Profibus-DP slave communication module be connected ?

  10. What EASY power supply unit can be used to provide the DC control relays with a + 24V supply ?

  11. Which components are contained in the EASY620-TB-GB trainer box and in which languages is it available ?

  12. Is there a new version of EASY-SOFT for addressing the EASY204-DP ?

  13. Is there a software to support the PROFIBUS-DP link of the Easy control relay to the EASY204-DP module with a MOELLER control system PS4 / PS416 ?

  14. With which operating system is EASY-SOFT V3.1 compatible ?

  15. What is the name of the application module for data exchange between the EASY204-DP and PS4-341/PS416 ?

  16. Which EASY-SOFT version can be used for programming Profibus-DP Interface ?

  17. What is the EASY expansion unit for 2 additional relay outputs called ?

  18. Does the EASY202-RE expansion unit require its own voltage supply ?

  19. Which EASY types are approved by RINA (Registro Italiano Navale), the Italian register of shipping ?

  20. How can the maximum counter frequency of an EASY control relay be determined from the cycle time ?

  21. Where can the EASY documentation be obtained ?

  22. How do you know that an expansion device is connected to the EASY619 / 621- . . . ?

  23. Is there a software to support the PROFIBUS-DP link of the Easy control relay with the EASY204-DP module to the Siemens S7-300 ?

  24. How do I implement the DeviceNet interfacing of an Easy 600 to a SLC 500 from Allen Bradley ?

  25. Are there any starter training possibilities for networking with the EASY800?

  26. Can I connect different phases of a 230 V AC EASY basic unit to the power supply and to the inputs (e.g L1 to the power supply; L2 to I1 or L3 to I2) ?

  27. What are the components of the EASY822 Trainer Board?

  28. Can I connect different phases on a 230 V AC EASY expansion device to the power supply or to the outputs (e.g. L1 to supply, L2 to S1 or L3 to S2)?

  29. Can I connect different phases on a 230 V AC EASY expansion device to the power supply or to the inputs (e.g. L1 to supply, L2 to R1 or L3 to R2)?

  30. Does the EASY800 have an adapter for using the EASY600 Mini Trainer ?

  31. Which operating system is required for running EASY-SOFT V4.x?

  32. How many circuit connections can be wired on EASY412-..., EASY6..-... and EASY8..-... devices?

  33. How many texts and characters per text can be displayed on the display versions of EASY6..-... and EASY8..-... series devices?

  34. What is the permissible operating temperature of the EASY control relays?

  35. Which EASY types have shipping approvals for Germanischer Lloyd (GL)?

  36. Are there any EASY control relay versions with frequency counters, high-speed counters and incremental value counters?

  37. What is the maximum counter frequency range of the CF... function block on EASY8..-DC.. devices?

  38. How many operating menu languages are supported on the EASY412-..., EASY6..-... and EASY8..-... devices?

  39. Which timer relay functions can be implemented with the EASY412-..., EASY6..-... and EASY8..-... devices?

  40. How can the sequence depth be increased on EASY412-..., EASY6..-... and EASY8..-... devices ?

  41. How many sequences can be wired per circuit connection using EASY412-..., EASY6..-... and EASY8..-... devices ?

  42. Are there EASY DC device versions with more than 2 analog inputs ?

  43. How many EASY8..-... stations can be connected in the NET ?

  44. What is the range of the maximum counter frequency of the CH.. function block on EASY8..-DC.. devices ?

  45. What is the range of the maximum counter frequency of the CI.. function block on EASY8..-DC.. devices ?

  46. What data can be transferred on the NET with EASY8..-... devices ?

  47. Which operating modes are possible for EASY8..-... devices on the NET ?

  48. What is the maximum possible length of the NET and max. baud rate for EASY8..-... devices ?

  49. Is there a possibility / are there any accessories for a door / front mounting for EASY ?

  50. Why is EASY-SOFT dialing up an Internet connection while starting the online-help ?

  51. Which EASY control relay has the approval of the Germanischer Lloyd (GL) shipping classification?

  52. Is it possible to run EASY6...-...I/O expansion modules with EASY8...-... device versions?

  53. What resolution do the analog inputs and outputs of the EASY8..-DC.. devices have?

  54. How can I delete a comment line (Note) in EasySoft 4.xx?

  55. Do EASY DC versions have an analog output?

  56. Is there a separate EASY-SOFT V3.1 Help available for downloading?

  57. Which updates / upgrades are currently available for the different versions of EASY-SOFT?

  58. Is there a help file available for the EASY-SOFT V4.xx (English version) ?

  59. Is there an overview of the abbreviations of the easy800 function blocks?

  60. Is it possible to calculate the available memory in an easy800?

  61. How much memory is taken up by the associated function blocks, constants and circuit connections of an easy800 control relay?

  62. Is there an engineering guide for the easy800?

  63. Is there an Application Note for EASY 800?

  64. What is the meaning of the abbreviations of the function blocks for an easy800?

easy8_schaltplan easy8_schaltplan easy8_schaltplan easy8_schaltplan easy8_schaltplan easy8_schaltplan easy7_ausgaenge easy6_display easy5_speicher easy4_cursor easy3_funktionen easy3_funktionen easy3_funktionen easy3_funktionen easy2_eingaenge easy1_typ

How is the EASY205-ASI addressed ?

As with all ASI slaves, the EASY205-ASI is addressed using a hand-held addressing unit (with an adapter on a 2.5 mm connector), or directly from the master via the ASI bus, provided that this supports remote addressing (such as the LE4-505-BS1 ASI master with a suitable MOELLER PLC).


How much and which data can the EASY205-ASI exchange with the AS-Interface master ?

As with all AS-i-slaves, a maximum of 4 input bits, 4 output bits and 4 parameter bits (from the point of view of the AS-i-master) can be transported between the master and slave.

This means the following:

    EASY: Direction: AS-i-master:
    S1, S2, S3, S4 => 4 input bits
    R1;R2;R3;R4 <= 4 output bits
    R5;R6;R7;R8 <= 4 parameter bits

For the EASY control relay it doesn't matter if it is a connected expansion module, a digital expansion module or an AS-i-slave.


How do you use the contacts and coils designated as ?

When using expansion units, the designation for the inputs on the expansion units are changed to "R" and the outputs of the expansion units to "S". This therefore creates a clear delineation, so that accesses to the inputs and outputs of the expansion units can be identified more clearly in the circuit diagram.


Can the outputs of the EASY..-D.-T.. units be provided with short-circuit monitoring?

The following inputs can be used for monitoring the outputs of the relevant EASY types:

    EASY412-D.-T..:
    I16 = Central fault indication for outputs Q1 to Q4.
    EASY62.-D.-T..:
    I16 = Central fault indication for outputs Q1 to Q4.
    I15 = Central fault indication for outputs Q5 to Q8.
    EASY620-D.-TE:
    R16 = Central fault indication for outputs S1 to S4.
    R15 = Central fault indication for outputs S5 to S8.

If one of the inputs is switched to "1", there is a fault on at least one of the outputs.


Is there a demo version of EASY-Soft and what are its restrictions compared to the full version ?

The EASY home page offers a link (see below) to the EASY download area. Here you can download the demo version of EASY-Soft in different languages. The demo version does not support online functions or Help functions.

Link: Download the Easy-Software Demo-Version


How many circuit connections can EASY412-... and EASY6..-... units support ?

In EASY units each line in the circuit diagram is counted as a circuit connection. EASY412 units therefore offer the user a maximum number of 41 circuit connections and EASY6..-... units a maximum of 121.


How can the ″S″ outputs of the expansion units otherwise be used ?

If there is no expansion unit connected to the basic unit, the ″S″ outputs are still available for use as markers.


What languages are contained in the EASYSOFT upgrade, version 3.1 ?

The easysoft31upgrade_... is available in 6 languages:
d==>deutsch/German
e==>spanisch/Spanish
f==>französisch/French
g==>englisch/English
i==>italienisch/Italian
p==>portogiesisch/Portuguese


From which operating system version (OS) of an EASY6 can an EASY204-DP Profibus-DP slave communication module be connected ?

The EASY204-DP can be connected to all EASY6 . . . devices from OS version 2.4.


What EASY power supply unit can be used to provide the DC control relays
with a + 24V supply ?

The EASY400-POW power supply unit is avaible for this purpose:
Rated input voltage: 115/230 V AC
Rated output current: 1,25 A


Which components are contained in the EASY620-TB-GB trainer box and in which languages is it available ?

The EASY620-TB trainer box contains the following components:
1. EASY-PC-CAB programming cable
2. EASY620 mini trainer
3. 20 practice cards
4. Power supply unit
5. EASY-SOFT V3.0
6. AWB2528-1304 user guide
7. FB0200-004 wiring guide
It is available in German (D) and English (GB)


Is there a new version of EASY-SOFT for addressing the EASY204-DP ?

For this there a free update of EASY-SOFT V3.0/V3.01
to version 3.1.

Link: Upgrade to version 3.1


Is there a software to support the PROFIBUS-DP link of the Easy control relay to the EASY204-DP module with a MOELLER control system PS4 / PS416 ?

The S40-AM-K6-D/GB application module provides function blocks for the PROFIBUS-DP connection of the Easy control relay to the PS4-341 and PS416. The link is implemented using the EASY204-DP module.

Link: Application modules S40-AM-K6-GB


With which operating system is EASY-SOFT V3.1 compatible ?

Windows 95 / 98 and Windows NT 4.0 (Service-Pack 3 and higher).


What is the name of the application module for data exchange between the EASY204-DP and PS4-341/PS416 ?

Application module S40-AM-K6-D/GB.
Download of the application module with the link.

Link: S40-AM-K6-G application module


Which EASY-SOFT version can be used for programming Profibus-DP Interface ?

Version V3.1 and higher!


What is the EASY expansion unit for 2 additional relay outputs called ?

Type: . . . . . . . . EASY202-RE
Article-Nr.: . . . . 232186
Rating in A: . . . .8A (10A UL)


Does the EASY202-RE expansion unit require its own voltage supply ?

No: This is supplied directly from the basic unit.


Which EASY types are approved by RINA (Registro Italiano Navale), the Italian register of shipping ?
 

The following EASY types are approved by RINA:

    EASY618-AC-RE;
    EASY619-AC-RC;
    EASY619-AC-RCX;
    EASY619-DC-RC;
    EASY619-DC-RCX;
    EASY620-DC-TE;
    EASY621-DC-TC;
    EASY621-DC-TCX;


How can the maximum counter frequency of an EASY control relay be determined from the cycle time ?

     

Formula: fc = 0.8 : (2 x tc)

fc = maximum counter frequency (Hz)
tc = Cycle time (s)
0.8 = Safety factor


Where can the EASY documentation be obtained ?

Download with the link.

Link: EASY documentation


How do you know that an expansion device is connected to the
EASY619 / 621- . . . ?

If at least one contact R or contact/coil S is used in the circuit diagram, the basic unit assumes that an expansion device is connected.


Is there a software to support the PROFIBUS-DP link of the Easy control relay with the EASY204-DP module to the Siemens S7-300 ?

The S7-AM-K6-D/GB application module provides function blocks for the PROFIBUS-DP connection of the Easy control relay to the S7-300. The link is implemented using the EASY204-DP module.

Link: Application module S7-AM-K6-D/GB


How do I implement the DeviceNet interfacing of an Easy 600 to a SLC 500 from Allen Bradley ?

The hardware interface of the Easy 600 is the “Easy 222-DN” module.
The respective data handling block for the SLC 500 can be found in the AN2700K17.
See the link below for download.

Link: AN2700K17GB


Are there any starter training possibilities for networking with the EASY800?

Yes, the EASY822 Trainer Board (Order no.: 263370 can be used) together with two network stations for training on programming and use of the NET network on the EASY800.


Can I connect different phases of a 230 V AC EASY basic unit to the power supply and to the inputs (e.g L1 to the power supply; L2 to I1 or L3 to I2) ?

In order to prevent the device from being destroyed, the supply and the input voltage must be connected to the same phase / phase conductor.


What are the components of the EASY822 Trainer Board?

The following components are contained in the EASY822 Trainer Board:

    1. 2x EASY822-DC-TC
    2. EASY800-PC-CAB programming cable
    3. 2x EASY620 Mini Trainer
    4. 2 training cards
    5. EASY400-POW
    6. EASY-SOFT V4.x

The EASY822 Trainer Board is fully wired and is supplied in a handy notebook case.


Can I connect different phases on a 230 V AC EASY expansion device to the power supply or to the outputs (e.g. L1 to supply, L2 to S1 or L3 to S2)?

The power supply of the expansion device and the power supply of the outputs S1... S6 are isolated.
Different phases can be used provided that the voltage between the conductors does not exceed 400 V +10%


Can I connect different phases on a 230 V AC EASY expansion device to the power supply or to the inputs (e.g. L1 to supply, L2 to R1 or L3 to R2)?

The power supply of the expansion device and the power supply for the inputs R1...R12 are not isolated.
The same phase must be connected.


Does the EASY800 have an adapter for using the EASY600 Mini Trainer ?

Yes, the EASY620 Mini Trainer can be used with the help of the EASY800-AK adapter kit (order no.: 262018).


Which operating system is required for running EASY-SOFT V4.x?

Windows 98, Windows NT 4.0 (Service Pack 6 or higher), Windows ME and Windows XP.


How many circuit connections can be wired on EASY412-..., EASY6..-... and EASY8..-... devices?

In EASY devices, each line in the circuit diagram counts as a circuit connection.
On EASY412-... devices the maximum number of wired circuit connections is 41,
on EASY6..-... devices max. 121 and EASY8..-... 256 circuit connections are possible.


How many texts and characters per text can be displayed on the display versions of EASY6..-... and EASY8..-... series devices?

EASY6..-... devices can display max. 8 user-defined texts of up to 48 characters each, and EASY800 devices can display max. 32 user-defined texts of up to 64 characters each.


What is the permissible operating temperature of the EASY control relays?
 

EASY control relays have an operating temperature range
from –25°C . . . +55°C.
(cold to IEC 60 068-2-1, heat to IEC 60 068 2-2)
Prevent condensation by means of suitable measures.


Which EASY types have shipping approvals for Germanischer Lloyd (GL)?

The following EASY types have GL approvals:

    EASY412-AC-R, EASY412-AC-RC, EASY412-AC-RCX,
    EASY412-DA-RC, EASY412-DC-R, EASY412-DC-RC,
    EASY412-DC-RCX, EASY412-DC-TC, EASY412-DC-TCX,
    EASY618-AC-RE, EASY618-DC-RE, EASY619-AC-RC,
    EASY619-AC-RCX, EASY619-DC-RC, EASY619-DC-RCX,
    EASY620-DC-TE, EASY621-DC-TC, EASY621-DC-TCX
     


Are there any EASY control relay versions with frequency counters, high-speed counters and incremental value counters?

Yes, EASY8..-DC.. devices have the following high-speed counter functions directly connected to the digital inputs ( I01 - I04 ):
4 x frequency counters, frequency measurement = CF.. (name of function block);
4 x high-speed counters, high-speed signal counting = CH.. (name of function block );
2 x incremental value counters, dual-channel incremental signal counting = CI.. (name of function block).


What is the maximum counter frequency range of the CF... function block on EASY8..-DC.. devices?

The max. counter frequency is 5kHz and the minimum frequency is 4Hz.
The pulse shape of the signal must be square wave.
The mark to space ratio is 1:1.


How many operating menu languages are supported on the EASY412-..., EASY6..-... and EASY8..-... devices?

EASY412-... devices support the following languages: D, GB, F, I,E
EASY6..-... and EASY800 devices support the following languages in addition: P, NL, S, PL, and TR.


Which timer relay functions can be implemented with the EASY412-..., EASY6..-... and EASY8..-... devices?

EASY412-... and EASY6..-... devices support the following functions:
on-delayed, on-delayed (random switching),
off-delayed,
off-delayed (random switching),
single pulse,
flashing.
EASY800 devices support the following functions additional:
on and off-delayed,
on and off-delayed (random switching).


How can the sequence depth be increased on EASY412-..., EASY6..-... and EASY8..-... devices ?

EASY412-... and EASY6..-... devices offer the user up to 16 markers and
EASY800 devices offer 96 markers for increasing the sequence depth.


How many sequences can be wired per circuit connection using EASY412-..., EASY6..-... and EASY8..-... devices ?

EASY412-... and EASY6..-... devices can wire up to 3 sequences and
EASY800 devices up to 4 sequences per circuit connection.


Are there EASY DC device versions with more than 2 analog inputs ?

Yes, EASY8..-DC-.. devices allow 4 of the 12 digital inputs to be used as analog inputs.


How many EASY8..-... stations can be connected in the NET ?

The maximum number in the NET is 8.


What is the range of the maximum counter frequency of the CH.. function block on EASY8..-DC.. devices ?

The maximum counter frequency is 5kHz.
The signals must be square wave signals, the pulse/pause ratio must be 1:1.


What is the range of the maximum counter frequency of the CI.. function block on EASY8..-DC.. devices ?

The max. counter frequency is 3kHz.
The signals must be square wave signals.
The mark to space ratio is 1:1.
The signals of channels A and B must have a 90 ° offset otherwise the count direction cannot be detected.


What data can be transferred on the NET with EASY8..-... devices ?

The following data can be transferred via the NET:
- Up to 32 double words
- Synchronise time, date
- Direct access to inputs and outputs
- Program download and upload via the NET


Which operating modes are possible for EASY8..-... devices on the NET ?

The following operating modes are possible:
A) 1 master (location 1, station address 1), up to 7 I/O net stations.
B) These I/O net stations can be I/O or intelligent stations.


What is the maximum possible length of the NET and max. baud rate for EASY8..-... devices ?

The maximum length of the NET is 1000 metres from the first to the last station. Baud rates of 10 KBit/s to 1000 KBit/s are possible depending on the length of the NET implemented.


Is there a possibility / are there any accessories for a door / front mounting for EASY ?

Yes, the following are available for door/front mounting:
A) Inspection window:

Type:SKF-FF4
For EASY type:EASY412...
Order No.:233780
or
Type:SKF-FF6
For EASY-type:EASY6... and EASY8…
Order Nr.:233781

B) Top-hat rail adapter for inspection window:

Type: SKF-HA
Number:2 per EASY
Order No.:233782


Why is EASY-SOFT dialing up an Internet connection while starting the online-help ?

Microsoft Compiled HTML Help (*.chm) requires the file >>HHActiveX.dll<<

    1. Download HHActiveX.dll
    2. Copy HHActiveX.DLL to "Windows->System".
    3. In the Run dialog box (Start, Run) type:
    "regsvr32 hhactivex.dll"


Which EASY control relay has the approval of the Germanischer Lloyd (GL) shipping classification?

The EASY4...-... / EASY6...-... control relays have obtained the approval of the Germanischer Lloyd (GL) shipping classification.
The certificate can be obtained via the Intranet as follows:
SERVICE -> Technical Data -> Product Declaration -> Approvals -> Search for EASY


Is it possible to run EASY6...-...I/O expansion modules with EASY8...-... device versions?

Yes, all EASY6..-... I/O expansions can be run with all EASY8..-... device versions.


What resolution do the analog inputs and outputs of the EASY8..-DC.. devices have?

The analog inputs and outputs have a 10-bit resolution. (0.01 V / 0-1023 Inc.).


How can I delete a comment line (Note) in EasySoft 4.xx?

Right-click the line and select Delete Note.


Do EASY DC versions have an analog output?

Yes, the following EASY8..-DC.. devices have an analog output:
1. EASY820-DC-RC,
2. EASY820-DC-RCX,
3. EASY822-DC-TC and
4. EASY822-DC-TCX


Is there a separate EASY-SOFT V3.1 Help available for downloading?

Yes, :
- Easy-Soft 3.1 Help menu, English

Link: EASY-HELP


Which updates / upgrades are currently available for the different versions of EASY-SOFT?

The following updates are currently available:
- Easy-Soft Upgrade from V4.00 / V4.01 V4.02 to V4.03, English
- Easy-Soft V3.1, Service Pack 4
- Easy-Soft Upgrade von V3.0 / V3.01 to V3.1, English
- Easy-Soft V3.0, Service Pack 2
- Easy-Soft V2.0, Service Pack to V2.1, English

Link: EASY-SOFT-Version


Is there a help file available for the EASY-SOFT V4.xx (English version) ?

Yes.
Please load the HELPG.CHM help file (Link: ftp://ftp.moeller.net/EASY/EASY-SOFT/helpg.chm) into your Moeller-Software -> EASY-SOFT 4 directory.
If a file with the same name exists, it will be overwritten.
Subsequently, you will be able to use the updated help in the EASY-SOFT V4.xx.

Link: EASY-SOFT helpfile


Is there an overview of the abbreviations of the easy800 function blocks?

Link: Application Note for EASY 800


Is it possible to calculate the available memory in an easy800?

Adobe PDF: Application Note for EASY 800


How much memory is taken up by the associated function blocks, constants and circuit connections of an easy800 control relay?

Link: Application Note for EASY 800


Is there an engineering guide for the easy800?

Link: Application Note for EASY 800


Is there an Application Note for EASY 800?

Link: Application Note for EASY 800


What is the meaning of the abbreviations of the function blocks for an easy800?

Link: Application Note for EASY 800

 

 

 

 